Filter Results By:

Products

Applications

Manufacturers

AC Sources

Waveform of an Alternating Current circuit is typically a perfect sine wave cycling up and down.

See Also: Programmable AC Sources


Showing results: 241 - 255 of 268 items found.

  • Digital Recorder

    HiRES - HIGHVOLT Prüftechnik Dresden GmbH

    The digital recorders HiRES are used to measure, store, and evaluate signals from up to 64 sources synchronously. Depending on the sensors used voltages, currents, temperatures, mechanical movements and various other signals can be measured. This measurement system features the ability to capture fast transient processes such as those occurring in impulse current tests on electrical devices or during switchgear testing. The system is also capable of measuring semistationary and periodic events such as DC voltage and AC voltage as well as superimposed semistationary, periodic and transient processes.

  • Power Line Meter

    Alpha Lab, Inc.

    The Line EMI Meter measures electromagnetic interference in a single-phase AC power line. It plugs into a wall outlet (mains socket) and requires no battery. It immediately displays total line noise in millivolts (range 1999 mV, resolution 1 mV) in the frequency range 10 KHz 10 MHz (the frequency limits at which sensitivity is of the maximum sensitivity). A speaker plays the sound of the EMI, amplitude demodulated, in order to identify the EMI source (such as an AM or shortwave radio station vs. a motor vs. an electric arc).

  • Fuel Quantity Testers

    Barfield Inc.

    Fuel capacitance systems are separated into two broad groupings, AC capacitance and DC capacitance. The source of these names derives from the type of signal processed by the fuel system amplifier. Barfield designs a universal tester for each type of system with the proper interface harnesses to access individual aircraft applications. Some of the various test and measurements include:*Insulation - Testing the wiring and probes*Fuel Tank Capacitance Measurement*Individual Probe Capacitance Measurement*Capacitance Simulation - Indicators and amplifiers*Indicators - Bench testing of remote units

  • Arc Ingintion Tester

    SCR ELEKTRONIKS

    The product is designed to carry out Arc Ignition Test as per IS/IEC 60947-1 Clause 8.2.1.1.2 (material used for electrical products). The adjustable current source is 230V AC @ 33A. The load is adjusted to get 32.5A at 0.5 power factor. Included on control unit are Digital Voltmeter, Digital Ammeter, Digital Power Factor Meter and Micro Controller based programmable Sequence Timer with LCD display for display & setting. The arrangement is made to mount the test piece with electrodes as per the specification given in the standard.

  • 24-Bit High-Resolution Dynamic Signal Acquisition and Generation Module

    PCI-9527L - ADLINK Technology Inc.

    The PCI-9527L is a high-performance, 2-CH analog input and 2-CH analog output dynamic signal acquisition board. This board is specifically designed for audio testing, acoustic measurement, and vibration analysis applications.The ADLINK PCI-9527L features two 24-bit simultaneous sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate up to 216 KS/s at high resolutions, making it ideal for higher bandwidth dynamic signal measurements. The sampling rate can be adjusted by setting the onboard DDS clock source to an appropriate frequency. All channels are sampled simultaneously and accept an input range from ±40 V to ±0.316 V. The PCI-9527L analog input supports software selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors.

  • Manual Oscillators

    MOS-01, -01A - Compact Power Company

    The MOS-01 manual oscillator module is used as a quality, general-purpose sinewave oscillator and digital readout monitoring system in the MAC-01, -02, or -03 AC Power Sources/Frequency Converters. The unit has guaranteed operating range of 20 HZ to 20 KHZ which is covered in three one-decade scales. The LCD digital metering system is switch-selectable to readout either frequency, voltage or current. A toggle switch selects the input for the attached AC Power Source/Frequency Converter to originate from the manual oscillator itself or from an external laboratory or programmable oscillator source. With oscillator mode switch in Internal position, the BNC connector delivers the signal to drive additional slave units or for oscilloscope sync or monitoring. BNC input/output is completely isolated with 1500 VAC breakdown and excellent common mode rejection. The oscillator modules must be factory installed and calibrated.

  • Materials Test Systems

    Ametek Scientific Instruments

    An impedance analyzer is a device that uses a programmable AC voltage / current source, together with voltage and current measurement circuits, to characterize sample impedance over a wide range of frequency. An example of this being the world famous Solartron Analytical 1260A Impedance Analyzer that provides EIS impedance characterization over more than 12 decades of frequency from uHz to tens of MHz. Impedance Analysis characterization is a key technology that enables new materials development for semiconductors, smart-materials, ferroelectrics, piezo-electrics, solid oxide, solid electrolytes, ceramics, polymers, OLED and many more materials.

  • HV Power & Transient Isolators

    B-1020-C - ROSS ENGINEERING CORPORATION

    These supply 120V or 240V AC continuous power for equipment that must operate while at a high voltage to ground or power source. For example, a fiber optic transmitter at the HV level for waveforms to be received and measured or recorded by grounded instrumentation might be powered by an isolation transformer secondary to primary either insulated by potting, oil or air. The low dielectric constant of air insulation provides lower capacitive coupling between the secondary and the primary or ground than would solid or oil insulation. The lower capacitance provides better isolation both at line frequency and especially at high frequency voltages such as lightning or switching transients.

  • Fiber Optic Transmission Systems

    B-1020-B - ROSS ENGINEERING CORPORATION

    Ross Engineering Corporation has developed a HV compact analog fiber optic transmitting and receiving system, with optional over-voltage limiting, designed to drive instrumentation from a DC to 1MHz signal source. The system is available with optional multiple input and output ranges of ±0-1V PK, 0-5V PK to 0-10V PK. It will also operate in conjunction with Ross Engineering Corporation’s high accuracy high voltage wideband voltage dividers, which are useful from DC to over 10MHz up to 1,000,000V PK at 0.01% to 3% accuracy. Transmitters and receivers can be powered by either AC or DC.

  • Phase Rotation Tester with Voltmeter

    885 PR - Standard Electric Works Co., Ltd

    ● 3 functions in one unit: Phase Rotation, Phase Presence, Voltmeter● LCD contact type Phase Rotation Tester● Large LCD to show phase rotation and phase presence● Check a wide range of three phase power sources● Voltage range for phase rotation test: 75~600V AC ● Frequency range: 40~400Hz● 6000-count voltmeter● Auto ranging Voltmeter AC/DC● Data hold function● Auto power off● Convenient stand for viewing● Easy to use● Comply with EN 61010-1 CAT III 600V EN 61010-2-033 EN 61326-1

  • DC Bias Current Power Supply

    TH1775 - Shenzhen Chuangxin Instruments Co., Ltd.

    TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.

  • High Accuracy Spectrophotocolorimeter

    LMS-3000 - Lisun Electronics Inc.

    • Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃

  • Conductive Footwear Tester

    SLTM-1 - Walter G. Legge Company Inc.

    SLTM-1 Conductive Footwear Tester checks conductive footwear automatically. The SLTM-1 Conductive Footwear Tester automatically and accurately measures the exact amount of resistance in conductive footwear and body grounding devices, ensuring a static control environment. It is ideal for dangerous, potentially explosive areas or areas in the electronic industry where static can destroy sensitive components. Stand on the foot plates and the unit’s direct-reading dial with graduated, color-coded scale indicates the exact amount of resistance. Shipped complete and ready to operate. Has 8 feet of 18-3 type SJ power cord that plugs into any grounded 120-volt AC power source. This unit measures 17 x 12 inches and weighs less than 6 1/2 lbs. All conductive footwear and body grounding devices, such as LEGSTATS, must be worn in pairs. SLTM-1 passes conductive footwear with resistance less than 2.5 MEG Ohm.

  • Multiple Output Bidirectional PSU

    LAB-MOBI - Electronic Test & Power Systems

    The LAB-MOBI is a series of multi channel High Power Bidirectional PSUs. Each system is able to operate as either a DC Source or a DC Electronic Load. This integrated approach features high dynamics enabling the user to switch seamlessly between quadrants. When sinking energy from the unit under test the LAB-MOBI automatically inverts the DC to AC and synchronises this output to the grid. Dedicated application modes are available for battery cycling and emulation, which can be used to implement specific test routines. Other common applications the LAB-MOBI is used for include testing electric motors, fuel cells, super capacitors and solar panels. Max. Volt. Output 1000V,Min. Power 60kW, Max. Power 500kW.

  • Power Supply Testers

    Qmax Test Technologies Pvt. Ltd.

    Power Supply Tester is an integrated package of hardware such as AC/DC Power Sources, DC Loads, Noise Measurement Unit, and DMM etc configured as per user applications, which makes it suitable for testing wide range of Power Supplies and provide economic solution for testing AC/ DC and DC/DC power supplies and converters. The Power Supply Boards that passed in the first level of screening for Go-No Go tests will undergo a second level testing. The second level of testing measures all the key parameters of the power supply such as line regulation, load regulation, efficiency etc and check whether the results are within the mentioned limit, if not declare the UUT (Power Supply Board Under Test) as a failed one.